In my laboratory experiments with inkjet-printed ultrasonic sensors on plates and on a tank, I reported a defect-localization error of about 1%. That number only means something once you know what sets it, so this post works through the physics of the method with a geometry I made up for the purpose. I will not unpack the details of the experiments here, since the full study is in a manuscript that has not yet been published. What I can do is show where a figure like 1% comes from, and where it would stop being achievable.
Where the sensors sit
The arrangement is simple. A source sends a short ultrasonic pulse into a plate. A few sensors on the surface listen. If the plate has a defect, such as a hole or a crack, some of the pulse reflects from it and arrives at the sensors after the pulse that went straight from source to sensor.

There is no imaging here. Each sensor reports one number, the time between the direct arrival and the echo, and the position of the defect has to be reconstructed from a handful of times. That is what makes the method cheap in hardware and unforgiving in timing.
One echo, one ellipse
Take a sensor R and a source S. The direct pulse travels the distance |SR|. The echo travels from S to the defect D and from D to R, a distance |SD| + |DR|. The extra time is the extra path divided by the wave speed u:
Δt = (|SD| + |DR| − |SR|) / u.
Fix Δt, and the defect must lie on the set of points whose two distances to S and R add up to a constant. That set is an ellipse with S and R at its foci. A second sensor gives a second ellipse, and the defect sits where they cross. The source also hears its own echo after a round trip 2|SD|/u, which fixes the distance from S alone and draws a circle.

Here are the numbers for the geometry in the drawing, which I chose arbitrarily. The plate is 300 by 200 mm. The source is at (150, 10) mm, the sensors at (10, 110) and (292, 120) mm, and the defect at (196, 128) mm. I assume u = 5.0 km/s, a round number of the right order for sound in aluminum. Then |SD| = 126.6 mm, so the source hears its echo after 50.7 μs. The excess delays are 28.3 μs at R1 and 8.7 μs at R2. Those three times, and the geometry, are all the information the method has.
The timing budget
Suppose I want the position to 1 mm. For the pulse-echo path, a 1 mm shift of the defect along the line from the source changes the round trip by 2 mm, which is 0.4 μs at 5 km/s. With an illustrative drive frequency of 50 kHz, one period is 20 μs, so I have to know when the echo arrives to about one fiftieth of a cycle. That is a demanding requirement for a pulse whose envelope is many cycles long.
Noise sets the limit. If I time a single zero crossing of a sinusoid of frequency f and peak amplitude A in white noise of rms σ, the timing jitter is roughly σ / (2π f A). At 50 kHz the factor 1/(2π f) is 3.2 μs, so the jitter in microseconds is 3.2 divided by the amplitude-to-noise ratio. For a jitter of 0.2 μs, a single crossing needs an amplitude-to-noise ratio of about 16, or 24 dB. Averaging over N crossings in a burst improves it by about √N, and that is the main reason to send a burst and not a single cycle. That is why the figure of merit for a sensor in this method is signal-to-noise ratio at the arrival time, and not volts.
Where the geometry helps and where it hurts
Timing errors do not turn into position errors one for one. Each timing measurement constrains position along its own gradient direction, and the position uncertainty depends on how well those directions span the plane. For independent timing errors, the covariance of the position estimate is σ_path² (JᵀJ)⁻¹, where J holds the gradients of the three path-length equations and σ_path is the timing noise multiplied by u. The square root of the trace of (JᵀJ)⁻¹ is a geometry factor. It is the number of millimetres of position error per millimetre of path error.

For the illustrative geometry the factor runs from 0.8 to 2.4. Over 90% of the plate it lies between 0.83 and 1.76, the median is 1.07, and it is 0.87 at the defect in the drawing. The best region is the open middle, where the three gradient directions are well spread. The worst regions are the lens-shaped zones along the lines from the source to each sensor. A defect on such a line returns an echo whose path is almost the same as the direct path, so the delay at that sensor barely changes as the defect moves, and that sensor’s equation carries little information. A small timing error then slides the solution along a long, shallow valley.
Two consequences follow. With a path timing noise of 0.2 μs at 5 km/s, which is 1 mm of path, a defect in the open middle is located to about 1 mm, and one in a lens-shaped zone to about 2 mm. On a path of 100 to 130 mm that is roughly 1% to 2%, so a figure of about 1% is what a timing jitter of this size would give. And the sensor layout matters as much as the sensors. Moving R1 so that it sits on the line through S and the likely defect region would turn a good geometry into a poor one.
Overlap and the baseline
The delays in the example, 8.7 μs and 28.3 μs, are shorter than a burst of five cycles at 50 kHz, which lasts 100 μs. The echo therefore arrives while the direct pulse is still going, and the two add. There is no clean onset to read. Two practical answers exist. One is to pick a feature, such as a zero crossing, that appears in both and accept that the echo shifts it by a fraction of a microsecond. That effect is the same size as the whole budget above. The other is baseline subtraction, which is standard in guided-wave monitoring. Record the plate before a defect appears, subtract that record from the later one, and what remains is the field scattered by the change. The cost is that the baseline drifts with temperature, because temperature changes the wave speed, so a baseline needs to be taken at a matching temperature or compensated.
The wave speed is part of the answer
Every distance in the method is proportional to u, so a 1% error in the assumed speed gives a 1% error in position, whatever the sensors do. A plate is a waveguide, and the speed at which an echo travels depends on the guided mode and on the product of frequency and thickness. Reviews of Lamb-wave inspection explain how that dependence arises and how to choose a mode and a frequency to keep it manageable (Su, Ye and Lu, 2006, doi:10.1016/j.jsv.2006.01.020). I treat u as a quantity that has to be measured for each plate, at each frequency and temperature, with a path of known length. I come back to that in the post on next experiments.
Solving for the position
The unknowns are the two coordinates of the defect and the equations are the three timing measurements. An iterative solver such as Newton–Raphson, or Gauss–Newton when there are more equations than unknowns, starts from a guess and corrects it using the Jacobian above. Two details matter. First, ellipses can cross at more than one point, so the starting guess decides which crossing is found. A starting guess inside the plate, and a third equation, both help. Second, the Jacobian is singular when the gradient directions line up, which is the same condition as the lens-shaped zones in the map, so a solver should stop and report when it sees that, and not return a number.
What I take from this
A localization error near 1% is plausible for a three-sensor array when the timing is good to a few tenths of a microsecond and the geometry is not degenerate, and the arithmetic above shows why. It is also why I describe the result as a laboratory result: it depends on timing noise, wave speed, mode and layout, each of which the next experiments have to control. How the sensors are made is the subject of the printing post.
Sources and links
- Project: inkjet-printed ultrasonic sensors for structural health monitoring. Overview on Spacecraft Structural Monitoring. The full study is in a manuscript that is not yet published in a journal.
- Su, Z., Ye, L. and Lu, Y. (2006). Guided Lamb waves for identification of damage in composite structures: a review. Journal of Sound and Vibration, 295. doi.org/10.1016/j.jsv.2006.01.020.
- Code and repositories on GitHub; publications on Google Scholar.
- This work is covered by one of three patent applications I have filed.
- Related posts: printing PVDF ultrasonic sensors on a desktop inkjet, next experiments for my printed ultrasonic sensors.